== Precautions and Advice ==
*Spray coating is easy, practical and is thus, the most widely used method *Generally, the best protection is obtained by a 2.0 mil thickness (+/-0.5 mil) will give the best protection*Rinse thoroughly with clean isopropyl alcohol or other cleaning solvent <ref>https://www.niccomp.com/resource/files/ceramic/NCD_HV_Guide_0903.pdf</ref>
While there are risks involved in conformal coating electronic assemblies, they can be mitigated. <br \>
We can avoid undue stresses which cause damage to components and assemblies by applying conformal coating of thickness within a recommended range.
Proper handling, electrical grounding, packaging, and transport of assemblies before, during, and after conformal coating will help to prevent mechanical and electrical damage to PCB assemblies. <br \>
The majority of risk is associated with general handling, transport, and processing of PCBs, factors that are present in other production processes and are not specific to conformal coating. Appropriate handling, electrical grounding, packaging, and transport of assemblies before, during, and after coating will help to prevent mechanical and electrical damage to PCB assemblies. <br \>
We can avoid undue stresses which cause damage to components and assemblies by applying conformal coating of thickness within a recommended range.