Negative-stiffness isolators
- Natural frequency range: 0.17 – 2.5 Hz
- Vertical Motion Isolation:
It uses a conventional spring connected to a Negative Stiffness Isolator (NSI) consisting of two bars hinged at the center. The stiffness of the isolator is K=KS-KN where KS is the spring stiffness and KN is the magnitude of a negative-stiffness which is a function of the length of the bars and the load P.
- Horizontal Motion Isolation:
The beam-columns have horizontal stiffness Ks with the weight load applied laterally. Due to this the lateral bending stiffness is reduced by the "beam-column" effect. This behavior is equivalent to a horizontal spring combined with an NSI so that the horizontal stiffness is K=Ks-Kn, and Kn is the magnitude of the beam-column effect.


If you are done reading this page, you can go back to Types of PVI Systems
References
This page has been inspired from https://www.minusk.com/content/in-the-news/Cleanroom_Technology_0412.html